ICB/PSA6/SDG&other/Placement/LR/32/19
August 11, 2020
Tender Code: ICB/PSA6/SDG&other/Placement/LR/32/19
Award Status: Partial Winners List
Award Date: 08/10/2020
Tender Award: Download
Unsuccessful Bidders:
Technical Evaluation Result:
Company Name: | |||||||||||
የኢትዮጵያ መድሃኒት አቅራቢ ኤጀንሲ | |||||||||||
Title: | |||||||||||
Ethiopian Pharmaceuticals Supply Agency | |||||||||||
Official Winner list (partial) | Page 1 of 1 | ||||||||||
For tender no,: ICB/PSA6/SDG&other/Placement/LR/32/19 | |||||||||||
Item No. | Description | Unit | Qty | Winner | Currency | Incoterm | Unit Price | Payment Terms | Delivery Time | Remark | |
Supplier | Country | ||||||||||
Lot I: Analyzer – Blood Grouping, Fully Automated | |||||||||||
Lot I | Analyzer – Blood Grouping, Fully Automated (reagents/consumables) | Test | 3,140,363 | Immucor | Germany | USD | FOB | 0.7188434656 | LC | As per bid | |
Microplates (barcoded) | 100 plates | 114.62 | LC | As per bid | 100plates/1100 test for (ABO grouping & RH typing&Reverse grouping), 100plates/2000test for IgG phenotyping, 100plates/2300test for high titre agglutinins (Anti-A (IgM)) or (Anti-B (IgM)) | ||||||
Diluent | 3x500ml | 117.22 | LC | As per bid | 1500ml/4000test for (ABO grouping&RH typing&Reverse grouping), 1500ml/4500test for high titre agglutinins (Anti-A (IgM)) or (Anti-B (IgM)) | ||||||
Immuclone Anti-A IgM | 10x10ml | 354.28 | LC | As per bid | 100ml/7000test | ||||||
Immuclone Anti-B IgM | 10x10ml | 354.28 | LC | As per bid | 100ml/7000test | ||||||
Immuclone Anti-AB IgM | 10x10ml | 354.28 | LC | As per bid | 100ml/7000test | ||||||
Immuclone RH-Hr Control | 10x10ml | 147.62 | LC | As per bid | 100ml/4000test | ||||||
Immuclone Anti-D rapid IgM | 10x10ml | 354.28 | LC | As per bid | 100ml/7000test | ||||||
Novaclone Anti-D IgM+ IgG Monoclonal blend | 10x10ml | 354.28 | LC | As per bid | 100ml/7000test | ||||||
Reference cells – 2 (Group A1 and B) | 2x10ml | 29.52 | LC | As per bid | 10ml/600test for (ABO grouping&RH typing&Reverse grouping), 10ml/200test for weak D | ||||||
Capture-R* Select | 480 wells | 104.2 | LC | As per bid | 480wells/220test for weak D, 480wells/60test for IgG phenotyping | ||||||
Capture-R* indicator Red cells | 10×11.5ml | 85.1 | LC | As per bid | 115ml/790test for weak D, 115ml/700test for antibody screening, 115ml/105test for antibody identification, 115ml/211test for IgG phenotyping | ||||||
Capture LISS | 10×11.5ml | 72.94 | LC | As per bid | 115ml/840test for weak D, 115ml/900test for antibody screening, 115ml/128test for antibody identification, 115ml/520test for IgG phenotyping | ||||||
Capture-R* Ready-Screen (I and II) | 240ul | 156.3 | LC | As per bid | 240ul/210test | ||||||
Capture-R* positive control serum (weak), Capture-R* negative control serum | 2×11.5ml | 79.89 | LC | As per bid | 11.5ml/200test for antibody screening, 11.5ml/400test for antibody identification | ||||||
Capture-R* Ready-ID | 30ul | 104.2 | LC | As per bid | 30ul/30test | ||||||
Negative control micro | 5ml | 21.26 | LC | As per bid | 5ml/140test | ||||||
Anti-Fy(a) micro | 5ml | 132.85 | LC | As per bid | 5ml/140test | ||||||
Anti-Fy(b) micro | 5ml | 177.14 | LC | As per bid | 5ml/140test | ||||||
Anti-S micro | 5ml | 132.85 | LC | As per bid | 5ml/140test | ||||||
Anti-s micro | 5ml | 132.85 | LC | As per bid | 5ml/140test | ||||||
Anti-k micro | 5ml | 177.14 | LC | As per bid | 5ml/140test | ||||||
Gammazyme-B | 10ml | 31.26 | LC | As per bid | 10ml/650test | ||||||
Monoclonal control | 10x10ml | 147.62 | LC | As per bid | 100ml/7000test | ||||||
Gammaclone Anti-jka | 5ml | 260.5 | LC | As per bid | 5ml/400test | ||||||
Gammaclone Anti-jkb | 5ml | 260.5 | LC | As per bid | 5ml/400test | ||||||
CorQCTM Eextend Standard | 10 ml | 39.94 | LC | As per bid | 10ml/180test for weak D, used as for the system | ||||||
System liquid concentrate | 10x500ml | 104.2 | LC | As per bid | Avg. 3-5ml/test | ||||||
Rely+onTMPer asafeTM | 10 pcs | 45.15 | LC | As per bid | 1pcs/3month/instrument | ||||||
Stir balls | 2×50 pcs | 50.36 | LC | As per bid | 1pcs used for one vial of reference cell/one vial of Capture-R* indicator Red cells | ||||||
Stir balls dispenser | pcs | 199.72 | LC | As per bid | 2pcs/instrument/year | ||||||
Lot II: Transfusion Transmissible Infections Testing Automated | |||||||||||
Item No. | Description | Unit | Qty | Winner | Currency | Incoterm | Unit Price | Payment Terms | Delivery Time | Remark | |
Supplier | Country | ||||||||||
Lot II | Transfusion Transmissible Infections Testing Automated (Reagents/Consumables) | Test | 3,349,720 | Abbott | Germany | USD | FOB | 1.473564926 | LC | As per bid | Air freight for reagents/consumables is FOC (free of charge) |
HBsAg reagent kit | kit | 231.81 | LC | As per bid | 200 test/kit | ||||||
HBsAg Calibrator | 3ml | 39.90 | LC | As per bid | 150ul/test | ||||||
HBsAg Control | 8ml | 40.20 | LC | As per bid | 150ul/test | ||||||
HIV Ag/Ab reagent kit | kit | 246.78 | LC | As per bid | 200 test/kit | ||||||
HIV Ag/Ab Calibrator | 3ml | 43.90 | LC | As per bid | 150ul/test | ||||||
HIV Ag/Ab Control | 8ml | 44.00 | LC | As per bid | 150ul/test | ||||||
ANTI-HCV reagent kit | kit | 450.40 | LC | As per bid | 200 test/kit | ||||||
ANTI-HCV Calibrator | 3ml | 40.90 | LC | As per bid | 150ul/test | ||||||
ANTI-HCV Control | 8ml | 41.00 | LC | As per bid | 150ul/test | ||||||
Syphilis reagent kit | kit | 216.61 | LC | As per bid | 200 test/kit | ||||||
Syphilis Calibrator | 3ml | 43.60 | LC | As per bid | 150ul/test | ||||||
Syphilis Control | 8ml | 43.70 | LC | As per bid | 150ul/test | ||||||
Multi-assay manual diluent | 100ml | 43.20 | LC | As per bid | If customer requires will be ordered (100 ml /210 samples at 1:500 dilutions) | ||||||
Concentrated wash buffer | 2x2L | 43.00 | LC | As per bid | 4L/approx.1000test | ||||||
Customer Maint kit | kit | 42.45 | LC | As per bid | 1kit/instrument | ||||||
HBsAg Manual Diluent | 100ml | 40.21 | LC | As per bid | Required if confirmatory test is done | ||||||
Pre-Trigger | 4x975ml | 40.40 | LC | As per bid | 150ul/test | ||||||
Probe Conditioner | 2×31.8ml | 42.90 | LC | As per bid | 31.8ml per month/instrument | ||||||
Reaction Vessels | 4000 pc | 42.60 | LC | As per bid | 1 pcs/test | ||||||
Closure cap for reagent | 100 pc | 44.19 | LC | As per bid | 3 caps/cartridge, if customer requires will be ordered | ||||||
Sample Cup | 1000 pc | 42.70 | LC | As per bid | 1 sample cup/sample, if customer requires will be ordered | ||||||
Trigger | 4x975ml | 46.2 | LC | As per bid | 300ul/test |
Reasons for Rejection
Company Name: | Document No: OF/TM/ HO-17 | ||||
የኢትዮጵያ መድሃኒት አቅራቢ ኤጀንሲ | |||||
Title: | |||||
Ethiopian Pharmaceuticals Supply Agency | Effective date : 13/09/2019 | ||||
Reasons for Rejection | Rev. No.: 0 | Page 1 of 1 | |||
Tender no,: ICB/PSA6/SDG&other/Placement/LR/32/19 | |||||
S. No. | Item Name | Name of rejected Bidders | Item no`s rejected | Reasons for rejection | Remark |
1 | Analyzer – Blood Grouping, Fully Automated | Bio-rad laboratories | Lot I | No EFDA product certificate | |
2 | Transfusion Transmissible Infections Testing Automated | Bio-rad laboratories | Lot II | No EFDA product certificate, double step dilution against single step dilution, no real time visual display | |
Diasorin | No EFDA product certificate, Bidder didn’t do interfacing with Blood Safety Information System in the blood bank service, Bidder didn’t provide introductory kits for training and equipment validation | ||||
SNIBE | Sample type; only serum against serum and plasma |