NCB/PSA6/COVID19-MOH/N95/MS/06/20 Amendment&Clarification
Tender Code: NCB/PSA6/COVID19-MOH/N95/MS/06/20 Amendment&Clarification
Tender Type: NCB
Closed Date: 12/29/2020 2:00pm
Opening Date: 12/29/2020 2:30pm
Product category: Medical Supplies
Download File: Download
- MEDICAL GOWN-Disposable Isolation Gown
- MEDICAL GOWN, AAMI LEVEL 3,
- Description
- MEDICAL GOWN, AAMI LEVEL 3,
Disposable isolation gowns are designed to be discarded after a single use and are typically constructed of nonwoven materials alone or in combination with materials that offer increased protection from liquid penetration, such as plastic films. Various forms of synthetic fibers (eg, polypropylene, polyester, polyethylene) are used for the construction of disposable isolation gowns. Rather than sewn, the garments are typically assembled using thermal, chemical, or mechanical seaming.
Reusable (multiuse) isolation gowns are laundered after each use and typically made of 100% cotton, 100% polyester, or polyester-cotton blends.
- Technical Specification
S.N | Characteristics | Specification OR Quality Requirement | Testing Method | Reference |
1) | Material Composition | Polyester film laminated with non woven fabric, has knitted collar and cuffs. | ES ISO1833- 11:2012 | CDC |
2) | Weight (GSM) | 40-50g/m2 | ES ISO3801:2000/
ASTM D3775-07 |
Ethiopia MoH |
3) | Covering size | full coverage with no open slits for protection in the front and back, both areas are critical areas for AAMI level
gowns |
Visual |
CDC |
4) | Liquid- penetration resistant | · Penetration ≤ 1.0 g and Hydrostatic pressure ≥ 50cm water column) and
· Seamless liquid proof and stain resistant |
· AATCC 42 and AATCC 127
· ASTM 1670 |
CDC and WHO |
5) | Tensile strength | 200N/CM | ASTM- D5035 | |
6) | Permeability of
fabrics to air |
200 Pa | ISO 9237 | |
7) | General | Excellent flame, lint and abrasion resistance |
ASTM- F2407 |
- MEDICAL GOWN, reusable isolation gowns
- Descriptions
Different study found that choosing reusable isolation gowns instead of disposable alternative as it has the financial advantages of reusable (cloth) textiles rather over their disposable (paper/synthetic) counterparts, and an environmental argument also there.
- Technical Specification
S.N | Material Characteristics | Technical Specification | Testing Method | Reference |
1. | Material Composition | Polyester with PVC coating | ES ISO1833- 11:2012 | International Journal of Engineering Research &
Technology (IJER |
2. | Weight (GSM) | 110-120 g/m2 | ES ISO3801:2000/
ASTM D3775-07 |
|
3. | Dimension | Depends on the size demanded by
FDRE MoE |
ASTM D668-12 |
WHO |
4. | Color | Light color | ||
8) | Liquid-penetration resistant | · Penetration ≤
1.0 g and Hydrostatic pressure ≥ 50cm water column) and · Seamless liquid proof and stain resistant |
· AATCC 42 and AATCC 127 · ASTM 1670 |
|
9) | Tensile strength | 200N/CM | ASTM- D5035 | |
10) | Permeability of fabrics to air | 200 Pa | ISO 9237 |
- Sourcing of Materials
For gown, AAMI LEVEL 3, Disp , it require 100% import finished product as there is no technology in fabric production (non-woven and finishing technology) and garment manufacturing technology.
For reusable isolation gowns it can be manufactured locally and imported the material based on the demand of FDRE MoE.
- Head cap operating disposable/Head Cover
3.1. Descriptions
Head cap is made of non-woven polypropylene material is designed for specifically for medical personnel in operation setting of COVID-19. Head Covers are designed to be discarded after a single use and should be destroyed after use.
- Technical Specification
S.N | Material Characteristics | Technical Specification | Testing Method | Reference |
1. | Material Composition | polypropylene | ||
2. | Weight (GSM) | 10-20 g/m2. | ||
3. | Dimension | Size: 21”
Thickness: 4± 0.3mm |
|
WHO |
4. | Liquid-penetration resistant | · Penetration ≤
1.0 g and Hydrostatic pressure ≥ 50cm water column) and · Seamless liquid proof and stain resistant |
|
6.3. Summary
DIMENSIONS Size: 21” Thickness: 4± 0.3mm
PRODUCT DESIGN: Head cap with anti-skid feature is made of non-woven polypropylene material weighing 10-20 g/m2. Product is non-sterile and for single use only.
INTENDED USE: The non-woven cap is designed specifically for medical personnel in operation settings. The caps are used during operations to effectively obstruct the patient’s blood, body fluid and exudation, to prevent bacterial infection.
INSTRUCTION FOR USE: The non-woven cap can be used only once. Covers should be used immediately after opening the package and should be destroyed after use. It is strictly prohibited using them if the package is damaged.
DISPOSAL: Dispose as medical waste in accordance with hospital, administrative and/or local government regulations and policies.
REGULATORY APROVAL: It should be approved by EFDA/FMOH
APPLICABLE STANDARDS: It’s applicable at Health Facility Level
STORAGE: Store in dry, ventilated condition, with ordinary temperature.